Insulation Calculator
Area divided by package coverage, plus an R-value thickness guide.
Also known as insulation rolls · batts quantity · insulation coverage
With the default inputs: Area to insulate 1000 ft² · Coverage per bag 88.1 ft² · Framing spacing 16 in etc.Insulation required 13 bags
Use your own dimensions ↓Inputs
Result
| Area with waste | 1100ft² |
| Coverage per bag | 88.1ft² |
| Framing spacing | 16in |
| Batt width | 15in |
| Part bag | 43ft² |
| R-13 reference | 3.5in |
| R-19 reference | 6.25in |
| R-30 reference | 9.5in |
How this is worked out
Bags = area x (1 + waste) ÷ package coverage, rounded up. The coverage figure has to come off the package, not a generic number: R-13 in 15 in width and in 23 in width differ more than twofold in coverage, and piece counts vary by manufacturer. Batt width must match the framing: 15 in for 16 in centres (an inch goes to each stud) and 23 in for 24 in centres. Wrong width means gaps everywhere and you may as well not have insulated. The R-value thicknesses are references only - about 3.5 in for R-13, 6.25 in for R-19 and 9.5 in for R-30, with actual thickness depending on the material. 10% waste is normal; irregular framing or lots of pipes and boxes takes it to 15%.
Next up: Skirting Board Calculator · Plasterboard Quantity Calculator
Reverse: known result, work out one input
Enter a target result; the other inputs stay fixed and this one is worked out.
Formula
| Bags = area × (1+waste) ÷ coverage per bag | round up |
| Batt width = framing spacing − 1 in | 15 for 16 in, 23 for 24 in |
| R-value ≈ thickness ÷ conductivity | fibreglass about 3.7 R per inch |
How to work it out
- Work out the area to insulate: net wall area, and ceiling length x width with no deduction for joists.
- Read the coverage figure printed on the package - not a generic value, since the same R-value in a different width differs more than twofold.
- Match the width to the framing: 15 in for 16 in centres, 23 in for 24 in centres.
- Bags = area x (1 + waste) ÷ coverage per bag, rounded up.
- Confirm the R-value by climate zone: walls R-13 to 21, ceilings R-30 to 60, floors R-19 to 30.
Where it goes wrong
- Buying the wrong batt width - 23 in in 16 in centres means cutting everywhere and more offcut than product; too narrow leaves gaps at every stud.
- Stuffing batts in tight - compression lowers the R-value. Fill the cavity snugly without squeezing.
- Ignoring gaps - a 5% gap loses 20-30% of effective R-value because air convects far faster than it conducts.
Material and cost
Fibreglass batts run about USD 0.50-1.20 per ft² by R-value and width, with mineral wool 30-50% more. Blown-in material is 0.80-1.50 per ft² but needs specialist equipment. Installed pricing is 1.50-3.50 per ft² for walls and 2.00-4.50 for ceilings; doing it yourself saves more than half.
On site
- Finish all plumbing, wiring and boxes before insulating - going back means stripping the lot.
- Leave 3 in clear around recessed light fittings: a fire requirement and it stops cables overheating.
- Fit the vapour barrier on the warm side, continuous and sealed. It is the key to avoiding mould, and fitted the wrong way it is worse than none.
Basis
- ASTM C665 Standard Specification for Mineral-Fiber Blanket Thermal Insulation
- IECC International Energy Conservation Code, Table R402.1.2 (U-factors by climate zone)
- EN 13162:2012+A1:2015 Thermal insulation products for buildings — Factory made mineral wool (MW) products
- ASHRAE 90.1, Table 5.5 (building envelope requirements)
FAQ
What R-value do I need?
What happens if the batts do not fit tightly?
Do I need a vapour barrier?
Cite this page
Use this format in reports, method statements or coursework. The link is permanent.
Building Calculator. Insulation Calculator. 2026-10-25. https://jianzhujisuan.com/en/insulation-batts