Waterstop Calculator
Joint length gives waterstop length, area and weight.
With the default inputs: Total joint length 120 · Waterstop width 300 · Steel waterstop thickness 3 etc.Waterstop purchase length 132.0 m
Edit the inputs below to recalculate.Inputs
Result
| Net joint length | 120.0m |
| Lap and waste | 10% |
| Purchase length | 132.0m |
| Surface area | 39.60m² |
| Steel weight per metre | 7.07kg/m |
| Total steel weight | 932.6kg |
| 6 m lengths required | 22bars |
| Steel per 100 m of joint | 707kg |
Length is the actual joint length times a lap and waste allowance. Both rubber and steel waterstop need laps: rubber is heat- or adhesive-spliced with at least 100 mm per joint; steel is welded with at least 50 mm full-penetration lap. Steel weight is width × thickness × 7850 kg/m³ — 300×3 mm gives 7.07 kg/m, worth memorising since it is bought by the tonne and installed by the metre. The strip must sit in the middle of the joint, half embedded each side, clamped with fixing bars so it cannot shift during the pour; displacement is the leading cause of leaks.
Reverse: known result, work out one input
Enter a target result; the other inputs stay fixed and this one is worked out.
Formula
| Purchase length | L = joint length × (1 + lap and waste) |
| Surface area | A = L × width |
| Steel per metre | g = width × thickness × 7850 |
| Total steel | G = L × g |
| 6 m lengths | n = ⌈L ÷ 6⌉ |
How to work it out
- Count the total joint length: horizontal construction joints at slab-to-wall by wall perimeter, vertical joints by wall height, and post-cast strips by running metre.
- Purchase length = joint length × (1 + lap allowance). Rubber waterstops lap 100-150 mm and must be hot-vulcanised; steel waterstops lap 50-100 mm and are welded.
- Steel waterstop weight = length × width (m) × thickness (mm) × 7.85, so 300 × 3 is 7.065 kg/m.
- Rubber waterstops are bought by the metre, commonly 300 × 8 and 350 × 10 (width × thickness); count embedded and surface-applied types separately.
- Add fixings: waterstops are tied to the reinforcement or held with purpose-made clamps at 0.5-1.0 m centres — a line that is routinely forgotten.
Where it goes wrong
- Allowing nothing for laps — waterstops must lap (rubber vulcanised, steel welded), 100-150 mm per joint, plus trimming at corners and ends; 10% is the floor.
- Pricing steel waterstop by area — it is bought by weight and length, and note the width is the developed width, not the height after folding.
- Letting the waterstop drift off centre — it must sit mid-joint with half its width each side; beyond 30 mm of displacement the seal is compromised, and displacement is the commonest site defect.
- Counting only embedded type — important work uses embedded plus surface-applied, and omitting the second halves the material.
Material and cost
Rubber waterstop 300 × 8 costs 25-50 CNY/m, steel-edged rubber 60-120, steel waterstop 300 × 3 35-55, swellable strip 15-30. Welding 10-20 CNY/m.
On site
- Concrete around the waterstop must be properly vibrated, especially the pocket underneath, or it forms a seepage path — the main cause of leaking construction joints.
- Rubber laps must be hot-vulcanised, never just glued; glued joints split within two years.
- At movement joints leave the waterstop free to move with clearance each side, or movement tears it.
Basis
- GB 50108-2008 Technical code for waterproofing of underground works, Chapter 5
- GB 50208-2011 Code for acceptance of underground waterproofing works, Chapter 5
- GB 18173.2-2014 Polymer waterproofing materials, Part 2 (waterstops)
FAQ
Why 3 mm plate rather than thinner?
What happens if the waterstop is displaced?
Rubber or steel waterstop?
Cite this page
Use this format in reports, method statements or coursework. The link is permanent.
Building Calculator. Waterstop Calculator. 2026-10-25. https://jianzhujisuan.com/en/waterstop