算BuildCalc

Lintel Load and Moment Calculator

Wall load above the opening, moment and steel estimate.

Quick answer

With the default inputs: Clear span 1.5 · Wall thickness 240 · Masonry density 19 kN/m³ etc.Mid-span moment 0.98 kN·m

Edit the inputs below to recalculate.
Lintel width mmLintel depth mm
Beam depth is the lintel itself; the wall above drives the load. Span is 1.05 × clear opening, not the opening width.

Inputs

kN/m³
N/mm²

Result

Mid-span moment
0.98kN·m
Effective wall height0.50m
Wall line load2.28kN/m
Self weight1.20kN/m
Total line load3.48kN/m
Support shear2.61kN
Effective depth h0165mm
Estimated steel area18mm²
Bars (Φ12 / Φ14)0.2 / 0.1bars

A lintel in masonry only carries the wall weight within a limited height - the masonry above arches over to the sides, so codes allow min(actual height, span/3) with a 45° spread. The moment uses a simply supported beam, ql²/8, with at least 240 mm bearing each end (and no less than the wall thickness). The steel area from M/(0.9·fy·h0) is a rough estimate that ignores the real compression block and minimum ratios - for scheme checks only. Formal design should use a precast lintel catalogue or a proper concrete calculation, and must consider any concentrated loads above.

Formula

Effective height = min(actual, span/3)45° spread
q = thickness × effective height × density + self weightkN/m
M = q·l²/8, V = q·l/2simply supported
As ≈ M / (0.9·fy·h0)rough estimate
1.5 m clear span, 240 mm wall, 19 kN/m³ masonry, 3 m of wall above, 240×200 lintel: effective height min(3.0, 0.5) = 0.5 m gives a wall load of 2.28 kN/m plus 1.20 kN/m self weight, q = 3.48 kN/m. M = 0.98 kN·m, V = 2.61 kN, h0 = 165 mm, about 18 mm² of steel - nominal bars suffice.

How to work it out

  1. Establish the wall height carried by the lintel: by 45° dispersion, take a third of the clear span or the actual height, whichever is less — only a triangular wedge above the opening is carried.
  2. Line load q = wall height × thickness × masonry unit weight (kN/m), plus 1.0-1.5 kN/m² for plaster and finishes.
  3. Moment M = q × L² ÷ 8 for a simply supported span L.
  4. Steel area As ≈ M ÷ (0.9 × h₀ × fy) with h₀ = depth − cover − d/2. This is a rough check; formal design follows the concrete code.
  5. Check shear too: V = q × L ÷ 2, adding stirrups or depth where capacity is short.

Where it goes wrong

Material and cost

Precast lintels run 60-120 each by span (about 90 for 1.5 m); cast in situ costs 450 per m³ of concrete plus steel and formwork, roughly 120-180 per metre. Precast is quicker but fixed in size; in-situ is flexible but needs formwork.

On site

Basis

FAQ

Why count only 0.5 m of a 3 m wall?
Masonry arches. The wall above the opening forms an arch and carries its weight to the piers either side instead of loading the lintel fully. Tests and codes accept the 45° spread, hence span/3. If a concrete beam or slab bears directly on the lintel, use the actual load - the simplification no longer applies.
How much bearing does a lintel need?
At least 240 mm each end and no less than the wall thickness. Shorter bearing crushes the masonry locally, showing up as corner cracking and settlement. Seismic regions require at least 360 mm and a reliable connection to ring beams or tie columns.
If the calculated steel is tiny, can it be omitted?
No. A small As means strength is not the issue, but minimum ratios and detailing still apply - typically not less than 2Φ10, or 2Φ12 per the catalogue - and the lintel must resist handling and shrinkage. It also frames the opening and ties to the wall either side.