Climbing Scaffold Calculator (Attached Lifting)

Enter the perimeter and storey height to get masts, frame height, standards and decking.

Quick answer

With the default inputs: Building length 30 m · Building width 16 m · Storey height 3.0 m etc.Lifting masts 21 pcsFrame height 13.5 m over 4.5 floors; 1242 m² of facade, only 14% of the floor area

Use your own dimensions ↓

Inputs

The frame runs right round the building; the perimeter is worked out from length and width
Short side; together with the length it sets the perimeter and the number of masts
Structural storey height, not clear height
levels
Frame height = floors covered x storey height. Code caps it at five storeys; 4.5 is the usual layout
Centre-to-centre spacing of lifting masts. A closed loop always turns a corner, so the 5.4 m kinked-run limit applies; 3.0-4.5 is usual
Usually 1.5 or 2.0, 2.0 maximum; each mast must land on a standard
Decking goes in at every lift; 1.8 is usual for all-steel frames
Clear distance between the inner and outer rows. Code caps it at 1.2 m; 0.6 or 0.9 is usual
levels
Used only for the gross floor area, so quoted rates per floor area can be checked

Result

Lifting masts
21pcs
Frame height13.50m
Facade protection area1242m²
Decking area662m²
Standards, two rows92bars
Standard length1242m
Ledger length1472m
Guide rail length284m
Hoists, one per mast21units
Protection per floor area0.144m²/m²
How this is worked out

Masts, standards and lifts are counted up to whole units, never carried as decimals: 92 m of perimeter at 4.5 m gives 21 masts. Do not use floor area as the denominator: this building has 8640 m2 of floor area against 1242 m2 of facade, a factor of 7.0.

Formula

PerimeterP = 2 x (length + width)
Frame heightH = floors covered x storey height, with H within five storeys and H x mast spacing within 110 m2
MastsN = perimeter / mast spacing, rounded up
Standardscount = perimeter / standard spacing x 2 rows, length = count x H
Liftsn = H / lift height rounded up; decking = P x frame width x n
Ledgerslength = 2 x P x n, one inner and one outer per lift
Facade protectionarea = P x H; guide rail length = masts x H
A 30 x 16 m building at 3.0 m storeys covering 4.5 floors with 4.5 m mast spacing: perimeter 92 m, frame height 13.5 m, 21 masts, 92 standards, eight lifts at 1.8 m, 662 m2 of decking, 1242 m2 of facade protection, 1472 m of ledgers and 284 m of guide rail. The same building at 18 storeys has 8640 m2 of floor area, so the facade is only 14% of it.

FAQ

How many lifting masts does a climbing scaffold need?
Divide the perimeter by the mast spacing and round up, not to nearest. A 30 x 16 m building has a 92 m perimeter, so at 4.5 m spacing it needs 21 masts; 20 would only allow 4.6 m each. The code sets only upper limits: 7.0 m on straight runs and 5.4 m on kinked or curved runs, with 3.0-4.5 m usual on site. Tighter spacing means more masts, lower load per mast, but more hoists and wall ties, so the cost goes up.
Is climbing scaffold hired by floor area or by facade area?
By facade protection area, or by mast-month, never by floor area. The two differ widely: a 30 x 16 m, 18-storey building has 8640 m2 of floor area but only 1242 m2 of facade, a factor of seven. At the same unit rate a floor-area quote is 259k against 37k on facade area, and the gap is not price, it is the wrong denominator. Fix the denominator in the contract before arguing price: facade area (perimeter x frame height) or lift area (perimeter x lift height x number of lifts).
Why is the frame limited to five storeys?
JGJ 202-2010 caps the frame height at five storeys, the product of frame height and mast span at 110 m2, and the frame width at 1.2 m. All three are mandatory. The reason is straightforward: a taller frame over a wider span carries a bigger overturning moment from wind and eccentric load, and all of it has to go into the structure through the wall ties. So more covered floors forces tighter mast spacing: at five floors of 3 m the 110 m2 rule caps the span at 7.3 m, which in practice means 7.0 m on straight runs and 5.4 m on kinked runs.
How does a climbing frame compare with a traditional tube-and-fitting scaffold per square metre?
They are not the same quantity, so a per-square-metre comparison is meaningless. A ground-based scaffold is priced on protection area at 21.4 kg of tube per square metre (27.0 kg including couplers), and the whole lot goes up at once. A climbing frame is mostly masts, guide rails and decking, and the same set climbs dozens of floors. Ask how many masts and how many climbs instead. To compare at all, put both on the same denominator, cost per square metre of floor area built: the ground-based figure grows with the number of storeys while the climbing figure barely does.

What to calculate next

These jobs are done back to back on site — follow the steps to work through the whole sequence.

Scaffold systems: climbing, tube-and-fitting, ringlockStep 1 of 3

  1. 1Climbing Scaffold Calculator (Attached Lifting)
  2. 2Scaffolding Calculator
  3. 3Ringlock Scaffold Calculator (by component)

Cite this page

Use this format in reports, method statements or coursework. The link is permanent.

Building Calculator. Climbing Scaffold Calculator (Attached Lifting). 2026-10-25. https://jianzhujisuan.com/en/climbing-scaffold

Results are estimating aids only and are not a design basis. Construction and final accounts must follow the drawings, the applicable standards and an approved method statement. Anything affecting structural safety, shoring or falsework must be checked by a suitably qualified engineer.