算BuildCalc Get a quote

Formwork Over-Height Calculator

Enter the support height and formwork contact area to get the over-height formwork quantity under the beam/slab and column/wall rules.

Quick answer

With the default inputs: Member type Slab · Support height 5.3 m · Formwork contact area 100 m²Over-height formwork 100.00 m²At 9.6 m with 100 m² of formwork: a slab counts 200 m², a column only 93.75 m²

Use your own dimensions ↓

Inputs

Not the storey height: slabs to the soffit (storey height minus slab thickness), beams to the beam soffit, columns and walls to the top of the member
m²
Paste the figure from the formwork area calculator; sum several members first

Result

Over-height formwork
100.00m²
MemberSlab (horizontal)
Support height5.30m
Height above 3.6 m1.70m
Over-height steps1cycles
Formwork contact area100.00m²
Over-height formwork (all area × 1)100.00m²
How this is worked out

Over-height starts from a 3.6 m support height, not the storey height: slabs to the soffit (storey height minus slab thickness), beams to the beam soffit, columns and walls to the top of the member. A 5.40 m storey with a 100 mm slab has a support height of only 5.30 m, and that 0.10 m can be the difference between one step and two. The two groups are measured completely differently. Beams and slabs are horizontal: the props are raised over their whole length, so the part below 3.6 m is propped up as well, and the quantity is the full contact area times the number of steps. Columns and walls are vertical: the side forms are built up in lifts, the support below 3.6 m is unchanged, and only the lifts above are stiffened, so the quantity is the sum of each segment area times its own step count. At 9.6 m with 100 m² of formwork, a slab is measured at 200.00 m² while a column comes to only 93.75 m² - one is double the contact area, the other is below it. Part steps round up: 6.60 m is exactly one step, 6.61 m becomes two. Tie columns, ring beams and large steel-panel walls are excluded from over-height formwork, and over-height for wall and slab construction joints is added into the corresponding wall or slab quantity. The 3.6 m line is a pricing threshold only; the 5 m hazardous-works line and the 8 m expert-review line are separate and neither replaces it. Take the contact area from the formwork area calculator and sum several members before entering it.

Formula

ThresholdApplies only above a 3.6 m support height
Steps (beams, slabs)n = ⌈(support height − 3.6) ÷ 3⌉, part steps round up
Quantity (beams, slabs)A = full contact area × n
Steps (columns, walls)3.6-6.6 m = 1, 6.6-9.6 m = 2, 9.6-12.6 m = 3 ...
Area per segmentAᵢ = full contact area × segment height ÷ support height
Quantity (columns, walls)A = Σ(Aᵢ × steps of that segment)
Excluded membersTie columns, ring beams, large steel-panel walls
A 100 m² slab under a 5.40 m storey with a 100 mm slab: support height 5.30 m, 1.70 m over, one step, so 100.00 m² of over-height formwork. Four 500×500 columns at the same storey have 43.20 m² of formwork: 1.80 m over, measured on that band only at 14.40 m² — taking the full height times one step would give 43.20 m², over by 28.80 m².

FAQ

Where does over-height formwork start? Is 3.6 m the storey height or the support height?
It is the support height of 3.60 m, not the storey height and not the clear height. Measure to the slab soffit for slabs (storey height minus slab thickness), to the beam soffit for beams (storey height minus beam depth), and to the top of the member for columns and walls. A 5.40 m storey with a 100 mm slab has a 5.30 m support height; in a beam-and-slab floor the beam soffit may sit at only 5.40 − 0.70 = 4.70 m. Using the storey height overstates it, using the clear height understates it.
Why do beams and slabs take the full area while columns and walls take only the band above 3.6 m?
Because the support works differently. Beams and slabs are horizontal, carried on a full grid of props: raise the floor and every prop is extended and extra ledgers added, including below 3.6 m, so the quantity is the full contact area times the number of steps. Columns and walls are vertical, their side forms built up lift by lift: the support below 3.6 m is unchanged and only the lifts above receive extra bracing, so each segment area is counted with its own step multiplier. At 9.6 m with 100 m² of formwork, a slab is measured at 200.00 m² and a column at only 93.75 m² — one is double the contact area, the other is below it.
How are the steps counted? Is 1.8 m over already one step?
Yes. Part steps round up: for beams and slabs n = ⌈(support height − 3.6) ÷ 3⌉, so anything from 0.1 m to 3.0 m over is one step and 3.1 m over is two. For columns and walls the bands are 3.6-6.6 m for the first step, 6.6-9.6 m for the second, 9.6-12.6 m for the third. That makes 6.60 m exactly one step and 6.61 m two — one centimetre at the threshold doubles the quantity.
Do tie columns and ring beams attract over-height formwork?
No. Tie columns, ring beams and large steel-panel walls are expressly excluded from over-height formwork, because their support does not rise with the storey. This is the easiest item to over-claim across a whole building: a 30-storey block has 200-400 tie columns, and counting each as over-height inflates the total substantially. Wall and slab construction joints are the opposite case — their over-height is added into the corresponding wall or slab quantity, never listed separately.
Are the 3.6 m, 5 m and 8 m thresholds the same thing?
No — three lines, three different purposes, none replacing another. 3.6 m is the pricing line: above it, over-height formwork is paid separately. 5 m is the hazardous-works line (MOHURD circular 31 of 2018): a support height of 5 m or more, or a span of 10 m or more, or a total load of 10 kN/m² or more, or a line load of 15 kN/m or more — any one triggers a dedicated method statement. 8 m is the expert-review line: 8 m or more in height, or an 18 m span, or 15 kN/m², or 20 kN/m, and a panel must be convened. A 4.5 m storey therefore attracts over-height formwork but is not yet hazardous works, while an 8.5 m storey needs both the money and the panel.

What to calculate next

These jobs are done back to back on site — follow the steps to work through the whole sequence.

Over-height formwork: area to proppingStep 1 of 3

  1. 1Formwork Over-Height Calculator
  2. 2Formwork Prop Calculator
  3. 3Ringlock Shoring Calculator (Slab Soffit)

Cite this page

Use this format in reports, method statements or coursework. The link is permanent.

Building Calculator. Formwork Over-Height Calculator. 2026-10-25. https://jianzhujisuan.com/en/formwork-superhigh

Results are estimating aids only and are not a design basis. Construction and final accounts must follow the drawings, the applicable standards and an approved method statement. Anything affecting structural safety, shoring or falsework must be checked by a suitably qualified engineer.